Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Still deciding? Get samples of US$ 720/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment methods: | |
---|---|
Support payment in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
HP200M7 | HP200M7C | HP250M7 | HP250M7C |
Tank | ||||
Total cylinder capacity(L) |
194
|
185
|
250
|
240 |
Tank Max pressure(kPa) |
700
|
|||
Rated voltage/frequency(V/Hz) | 220-240V/50Hz | |||
Corrosion protection | Magnesium rod | |||
Insulation protection rating |
IPX4
|
|||
Performance | ||||
COP@7°C(EN16147) |
3.2
|
3.2
|
3.23
|
3.21 |
COP@14°C | 3.6 | |||
Power input by electric backup(W) | 1500 | |||
Rated power input by heat pump(W) | 320 | |||
Maximum power input by heat pump(W) | 535 | |||
Maximum power input(W) | 2035 | |||
Heating water capacity(L/h) | 24 | |||
Heating up time(10°C/55°C)@7°C(h) | 7 |
6.8
|
10.5
|
10.3 |
Default temperature setting(°C) | 65 | |||
Temperature setting range with heater(°C) | 35-75 | |||
Maximum temperature output for the heat pump only(°C) | 65 | |||
Max working pressure of refrigerant(MPa) | 1.0/3.3 | |||
Refrigerant type/weight(kg) | R290/0.15 | |||
Sound power level *@1 metre(dB(A)) | 50 | |||
V40(L) | 239 | 228 | 307 | 295 |
Ambient temperature of heat pump(°C) | -7-45 | |||
Dmensions and connections | ||||
Water inlet and outlet connection | Rp 3/4 | |||
TPR valve connection | Rp 3/4 | |||
Drain & water inlet connection | Rp 3/4 | |||
Product dimensions(mm) | 600*620*1694 | 600*620*1694 | 600*620*1989 | 600*620*1989 |
Packing dimension with pallet(mm) | 736*695*1940 | 736*695*1940 | 736*695*2250 | 736*695*2250 |
Net/gross weight(kg) | 86/109 | 96/119 | 98/121 | 107/131 |
Filled weight of the appliance(kg) |
281
|
282
|
347
|
349 |
*THE COP was measured under test conditions with an ambient air temperature of 20°C/15°C (Dry Bulb/Wet Bulb) and heating of the water from 15°C to 55°C during water heater operation.
*The noise level was measured at 1 m from the water heater during a Noise Test conducted to Standard GB/T 23137 in a hemi-anechoic chamber with in a laboratory.
|