Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 50-70°C |
Still deciding? Get samples of US$ 799/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
HP200M3
|
HP250M3
|
HP250M3C
|
Tank
|
|||
Tank volume(L)
|
195
|
246
|
240
|
Rated voltage/frequency(V/Hz)
|
230V/50Hz
|
230V/50Hz
|
230V/50Hz
|
Tank rated pressure(bar)
|
7
|
7
|
7
|
Extra exchanger design/area
|
No
|
No
|
1m2
|
Corrosion proof
|
Magnesium anode
|
Magnesium anode
|
Magnesium anode
|
Performance
|
|||
Type of extraction
|
Ambient/Exterior
|
Ambient/Exterior
|
Ambient/Exterior
|
COP@7°C(EN16147)
|
3.04
|
3.02
|
3.10
|
COP@15°C(EN16147)
|
3.39
|
3.41
|
3.56
|
Tapping cycle (EN16147)
|
L
|
L
|
L
|
Electric backup power (W)
|
1500
|
1500
|
1500
|
Average input - heat pump only(W)
|
495
|
495
|
495
|
Maximum input- heat pump only(W)
|
625
|
625
|
625
|
Maximum power input (W)
|
2125
|
2125
|
2125
|
Standby power input/ Pes(W)
|
27
|
27
|
27
|
Vmax
|
224
|
311
|
332
|
Heating up time (h)(@7°C)
|
5h30
|
7h21
|
5h55
|
Heating up time (h)(@15°C)
|
4h41
|
6h10
|
6h
|
Default temperature setting(°C)
|
55
|
55
|
55
|
Temperature setting range with heater(°C)
|
35-75
|
35-75
|
35-75
|
Temperature setting range heat pump only(°C)
|
35-65
|
35-65
|
35-65
|
Refrigerant type/Weight (kg)
|
R134a/0.9
|
R134a/0.9
|
R134a/0.9
|
Noise power dB(A)
|
57
|
58
|
59
|
Working temperature-system(°C)
|
-7-35
|
-7-35
|
-7-35
|
Dmensions and connections
|
|||
Product Dimensions (D*W*H mm)-Tank
|
600*629*1692
|
600*629*1987
|
600*629*1987
|
Packing Dimensions (D*W*H mm)-Tank
|
736*695*1940
|
736*695*2250
|
736*695*2250
|
Gross weight (kg)-Tank/external unit
|
103
|
116
|
132
|
Net weight (kg)-Tank/external unit
|
91
|
102
|
119
|
Load qty.40HQ
|
51
|
51
|
51
|
*The COP and noise level data was tested in Haier lab.
|